Yokogawa 701260 High Voltage Isolation Input Module

$ 475.2

Availability: 100 in stock
  • Brand: Yokogawa
  • All returns accepted: Returns Accepted
  • Condition: Sold As Is
  • Model: Yokogawa 701260
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • MPN: Does Not Apply
  • Item must be returned within: 30 Days
  • Restocking Fee: No

    Description

    Yokogawa 701260 High Voltage Isolation Input Module
    *High-Voltage 100 kS/s 16-Bit Isolation Module (with RMS) (701260) 850 V (DC+AC peak) direct input, RMS mode Accuracy of 0.25%. 2 Channel Input Module for the Yokogawa DL750.
    -Input couplings AC, DC, GND, AC-RMS, DC-RMS
    -Maximum sampling rate 100 kS/s
    -A/D conversion resolution 16 bits (2400 LSB/div)
    -Input type Isolated unbalanced
    -Frequency range (¿3 dB) Waveform measurement mode DC, up to 40 kHz
    -RMS measurement mode DC, 40 Hz to 10 kHz
    -Input range (10:1) 200 mV/div to 2000 V/div (in steps of 1, 2, or 5) (1:1) 20 mV/div to 200 V/div (in steps of 1, 2, or 5)
    -Effective measurement range 20 div (display range 10 div)
    -DC offset ±5 div
    -Maximum input voltage (1 kHz or less) In combination with 700929 Probe (10:1) 1000 V (DC + AC peak)
    -In combination with 701901+701954 (1:1) 850 V (DC + AC peak)
    -Maximum allowable in-phase voltage In combination with 700929 (10:1) H side: 1000 Vrms (CAT II) 4, L side: 400 Vrms (CAT II)
    -In combination with 701901+701954 (1:1) H side: 700 Vrms (CAT II) 7, L side: 400 Vrms (CAT II)
    -Direct input (when using a cable which doesn't comply with the safety standard) H/L sides: 30 Vrms (42 V DC + ACpeak)11
    -DC accuracy (waveform measurement mode) ±(0.25% of 10 div)
    -DC accuracy (RMS measurement mode) ±(1.0% of 10 div)
    -AC accuracy (RMS measurement mode) Sine wave input ±(1.5% of 10 div)
    -Crest factor of 2 or less ±(2.0% of 10 div)
    -Crest factor of 3 or less ±(3.0% of 10 div)
    -Input impedance 1 MW ± 1%, approx. 35 pF
    -Connector type Isolated type BNC connector
    -Input filter OFF, 100 Hz, 1 kHz, 10 kHz
    -Temperature coefficient (waveform measurement mode)
    -Zero point ±(0.02% of 10 div)/°C (typical value)
    -Gain ±(0.02% of 10 div)/°C (typical value)
    -Response time (RMS mode) Rise (0 to 90% of 10 div) 100 ms (typical)
    -Fall (100 to 10% of 10 div) 250 ms (typical)
    -Crest factor (only at RMS measurement) 3 or less
    -Please use 701901 (1:1 safety adapter lead) or 700929 (10:1 safety probe), which complies with the safety standard, for high-voltage input.